Influence of Specimen Design on Maximum Heating Rate and Temperature Variation During Induction Heating in an 805L Dilatometer

Wednesday, September 15, 2021: 1:30 PM
100 (America's Center)
Prof. Robert L. Cryderman , Colorado School of Mines, Golden, CO
Mr. Tareq Eddir , Fluxtrol Inc., Auburn Hills, MI
Mr. Finn Bamrud, Student , Colorado School of Mines, Golden, CO
Mr. Robert C. Goldstein , Fluxtrol Inc., Auburn Hills, MI
Commercially, carbon steels are scan induction heated at heating rates on the order of 1,000 oCs-1 for surface hardening. The high precision 805L dilatometer employs induction heating and is often used to study transformation characteristics and prepare test specimens for metallurgical analysis. However, heating the commonly used 4 mm diameter by 10 mm long specimens at rates above 50 oCs-1 results in non-linear heating rates during transformation to austenite and large transient temperature variations along the specimen length. These limitations in heating rate and variances from ideal uniform heating can lead to inaccurate characterization of the transformation behavior compared to commercial induction hardening practices.

In this study it is shown that changing the specimen design to a thin wall tube allows faster heating rates up to 600 oCs-1 or higher and modifies the pattern of temperature variations within the test sample. The response of selected specimen geometries to induction heating in the dilatometer is characterized by modelling and tests using multiple thermocouples are used to verify the models. It is demonstrated that the use of properly designed tubular test specimens can aid in more accurately establishing transformation characteristics during commercial induction hardening.

See more of: Induction Heat Treating II
See more of: Technical Program