Metallurgical evaluation of cracked alloy 718Plus bolted joints from 2 development gas turbines

Monday, September 30, 2024: 3:40 PM
26 B (Huntington Convention Center)
Mr. William Rossey , GE Aerospace, Cincinnati, OH
During development engine testing two alloy 718Plus parts were found cracked after relatively low hours of testing. The investigation covers the fracture morphology, associated degradation mechanism, high level microstructure/processing, operating environment, and loading related to determining the root cause.
See more of: AEROSPACE FAILURES
See more of: Failure Analysis