D. Sanchez, S. King, L. Halbleib, M. Walsh, Sandia National Laboratories, Albuquerque, NM
Hysol is an underfill encapsulant used in the manufacturing of weapon components. In July 2003, components began to display incompletely cured encapsulant regions. A team was formed to investigate the problem using statistical experimental design techniques, such as Design of Experiments (DOE). This paper describes the success of experimental design in a manufacturing environment.
Summary: Hysol is an underfill encapsulant used in the manufacturing of weapon components. In July 2003, components began to display incompletely cured encapsulant regions. A team was formed to investigate the problem using statistical experimental design techniques, such as Design of Experiments (DOE). This paper describes the success of experimental design in a manufacturing environment.