The 35th International Symposium for Testing and Failure Analysis (November 15-19, 2009) of ASM

Back to "Session 1: Emerging Concepts" Search
  Back to "Symposium" Search  Back to Main Search

Tuesday, November 17, 2009 - 11:15 AM

Subsurface Imaging of Multi-Level Integrated Circuits Using Scanning Electron Acoustic Microscopy

L. Meng, J. C. H. Phang, Centre for Integrated Circuit Failure Analysis and Reliability (CICFAR), National University of Singapore, Singapore, Singapore; A. G. Street, inscopelabs, Singapore

View in PDF format

Summary: Scanning Electron Acoustic Microscopy has been used to generate high-resolution images of subsurface features at different depths in multi-level integrated circuits. Significant improvements in SEAM contrast, spatial resolution and depth discrimination have been demonstrated.